|
|
|
|
|
Nitrate Probe Configurator Instructions:
|
|
|
|
|
1
|
Select the type of waterbody
to be monitored.
|
|
2
|
Select parameters to be
measured from dropdown list:
1- "Nitrate NO3-N" for NO3-N, NO3, NOx-N, NOx
2- "Nitrate NO3-N & Turbidity & More" for NO3-N,
NO3, NOx-N, NOx, UVT254, UVT254n, SAC254, CODeq, BODeq, TOCeq, DOCeq, Turb,
TSSeq
3- "Nitrate NO3-N & Nitrite NO2-N & More"
for Nitrate NO3-N, Nitrite NO2-N, CODeq, BODeq, DOCeq, TOCeq,TSSeq, KHP,
SAC254, COD-SACeq, BOD-SACeq
|
|
3
|
The recommended probe type
based on your input above.
|
|
4
|
Input the maximum NO3-N
(mg/l-N) expected value in the waterbody to be monitored. (0 to 200 mg/l-N).
|
|
5
|
This is the recommended path
length based on your input, the NO3-N range and the maximum turbidity value
supported by this path length are displayed. You can select "Additional
Lens Sockets" below for more path lengths if needed. The sockets used
for the path length selected are also displayed. (Socket C = Socket installed
at the cable side) (Socket S = Socket installed at the sensor side). (PLA C =
Path Length Adapter cable side). (PLA S = Path Length Adapter Sensor side).
|
|
6
|
Select probe material type.
Titanium is recommended for salt water use.
|
|
7
|
Select between permanently
fixed or detachable field cable. Detachable field cable is highly
recommended.
|
|
8
|
If you selected the
"Fixed" cable option above, input the fixed cable length from
dropdown list: 2m, 10m, 20m, 25m,30m
and 35m.
|
|
9
|
If you selected the
"Detachable" cable option above, input the field detachable cable
total length needed in meters.
|
|
10
|
These filed shows if the unit requires an under water
connector or not. No input required.
|
|
11
|
Optional:
If the probe is to be mounted inside a pipe. Select if a pipe flange is
required or not.
|
|
12
|
Optional: Pipe
flange Material selected must be the same as the probe material.
|
|
13
|
Optional: Pressured
air can be used to clean the optics underwater. If you choose this option you
may want to consider purchasing the Tribox to control the air flow.
|
|
14
|
This is the part number and
description of the probe selected by the configurator based on your input
above. Add the quantity needed
|
|
15
|
This is the part number for
the detachable cable if selected based on your input. Add the quantity
needed.
|
|
16
|
If the
probe type is "OPUS" then Select water
Type from the dropdown menu
|
|
17
|
If the
probe type is "OPUS" then Select
Parameters from the dropdown list. The part number for the required
calibration is displayed. Add the
quantity needed.
|
|
18
|
Select "Yes" if you
want to use a wiper to clean the lenses. The wiper can not be used in
conjunction with a Flow-Cell. No wiper option is available for the 0.3 mm and
50 mm path lengths. Add the quantity needed.
|
|
19
|
This is the wiper blades kit
to use with the path length selected above.
|
|
20
|
Select "Yes" if the
probe is to be connected to SDI-12 Datalogger. Add the quantity needed.
|
|
21
|
The SDI-12 adaptor is required
for SDI connection.
|
|
22
|
To connect the probe to a PC
for setup, download or spot checking select an interface from the dropdown
menu. The G2plus interface is Highly
recommended as it connects the probe directly to any USB3.0 port with no external
power required. Add the quantity needed.
|
|
23
|
Choose "Yes" if you
have selected the detachable cable option so you do not have to remove the
field cable when removing the probe from the field for calibration, setup or
download.
|
|
24
|
Optional sensor guard to
protect the wiper and the lenses. Add the quantity needed.
|
|
25
|
Select "Probe flow
cell" "only". No panel
mount and no ultrasonic cleaning. Based on the path length selected. Add the
quantity needed.
|
|
26
|
Select "Probe flow
cell" "with panel"
mount and no ultrasonic cleaning. Based on the path length selected. Add the
quantity needed.
|
|
27
|
Select "Probe flow
cell" "With Panel & USC" (Panel mount & UltraSonic
Cleaning). Based on the path length selected. Not available for 50 mm path
length. Add the quantity needed.
|
|
28
|
This is the part needed to
calibrate the probe. Add the quantity needed.
|
|
29
|
Select "Yes" if you
want a deployment Buoy. Add the quantity needed.
|
|
30
|
Select "Yes" if you
want the mounting clamps to mount the probe to a wall. Add the quantity
needed.
|
|
31
|
This cable can extend the
length of the field cable overground and can not be submerged. Select cable
length from dropdown list. Add the quantity needed.
|
|
32
|
The lenses on the NICO and
OPUS can be replaced by the end user for damaged lenses or to upgrade to a
different path length.
1- Select the new path length from the dropdown list.
2- Select material type from the dropdown list.
3- "Cable side" Socket mounted on the cable side is
displayed.
4- "Sensor side" Socket mounted on the sensor side is
displayed.
5- "PLA Cable side" Path Length Adapter on the cable side is
displayed.
6-"PLA Sensor side" Path Length Adapter on the sensor side is
displayed.
Note: 10-50 mm Path Length is the 10 mm Path Length downsized from 50 mm
Path Length option
Add the quantity needed.
|
|
33
|
Select path length from dropdown list for
additional wiper blades. Add the quantity needed.
|
|
34
|
Select a Tribox3 controler
with or without WIFI option. Add the quantity needed.
|
|
35
|
Select a Tribox mini controler
with or without WIFI option. Add the quantity needed.
|
|
36
|
Add additional items. Add
description, Part number, Quantity and Price for each.
|
|
37
|
Add additional items. Add
description, Part number, Quantity and Price for each.
|
|
38
|
Add additional items. Add description, Part number, Quantity
and Price for each.
|
|
39
|
Add additional items. Add description, Part number, Quantity
and Price for each.
|
|
40
|
Notes
|