This configurator will help you determine the equipment best suited to your application and requirements.  Nitrate & Nitrite.    
  Click on the second TAB for instructions    
  Back to NICO www.hydrotechzs.com Back to OPUS    
Nitrate Probe Configurator    
     
    Date:
  Phone:    
    First Last Name:   Email:    
    Ship to: Bill to:    
           
           
           
  1 Select water type:   
           
  2 Measured Parameters:   
   
  3 Probe type:            
  4 (NO3-N) (mg/l-N) max value:            
  5 Ideal path length -Range -Max Turb:        
    Socket C - Socket S - PLA C- PLA S:            
  6 Probe material:  
         
  7   Type:
           
  8 Field cable - M12: Fixed (m)
Xm=          
  9   Detachable  (m):        
  10 Connector:            
  11            No/Yes:
           
  12   Optional probe flange:   Material:
       
  13   Pressured Air:
         
     Probe Description:             Part #   Qty    
14
 
15
    Additional Accessories:              Part #   Qty    
  16 OPUS Calibrations: Water Type:
           
  17 Parameters:
       
  18 Wiper W55 V2: No/Yes:
       
  19   Blade size:        
  20 SDI-12 interface box:  
       
  21 SDI-12 cable adaptor:          
  22 Connect to a PC:  
       
  23 2 m Calibration cable:  
     
  24 Probe deployment guard:  
       
  25   Only:
     
  26 Probe flow cell: With Panel:
     
  27   With Panel&USC:
     
  28 Calibration shell (Valtub):          
  29 Deployment buoy (Float):  
       
  30 Wall mounting clamps:  
       
  31 Field cable extension: M12 to M12:
       
       New Path Length: 
Max Turb:        
      Material: 
           
  32 Additional lens sockets & PLAs:    Cable side:         
      Sensor side:        
      PLA Cable side:        
      PLA Sensor side:        
  33 Additional wiper blade:  
       
  34 TriBox3:  
       
  35 Tribox mini:  
       
 
    Other: Description Part #   Qty    
  36      
  37      
  38      
  39      
  40 Notes:      
                   
                   
                   
    http://www.hydrotechzs.com, Telephone:512-846-2893, Email: [email protected]     
     
    Nitrate Probe Configurator Instructions:
     
  1 Select the type of waterbody to be monitored.
  2 Select parameters to be measured from dropdown list: 
1- "Nitrate NO3-N" for  NO3-N, NO3, NOx-N, NOx
2- "Nitrate NO3-N & Turbidity & More" for NO3-N, NO3, NOx-N, NOx, UVT254, UVT254n, SAC254, CODeq, BODeq, TOCeq, DOCeq, Turb, TSSeq
3- "Nitrate NO3-N & Nitrite NO2-N & More" for Nitrate NO3-N, Nitrite NO2-N, CODeq, BODeq, DOCeq, TOCeq,TSSeq, KHP, SAC254, COD-SACeq, BOD-SACeq  
  3 The recommended probe type based on your input above.
  4 Input the maximum NO3-N (mg/l-N) expected value in the waterbody to be monitored. (0 to 200 mg/l-N).
  5 This is the recommended path length based on your input, the NO3-N range and the maximum turbidity value supported by this path length are displayed. You can select "Additional Lens Sockets" below for more path lengths if needed. The sockets used for the path length selected are also displayed. (Socket C = Socket installed at the cable side) (Socket S = Socket installed at the sensor side). (PLA C = Path Length Adapter cable side). (PLA S = Path Length Adapter Sensor side).
  6 Select probe material type. Titanium is recommended for salt water use.
  7 Select between permanently fixed or detachable field cable. Detachable field cable is highly recommended.
  8 If you selected the "Fixed" cable option above, input the fixed cable length from dropdown list:  2m, 10m, 20m, 25m,30m and 35m.
  9 If you selected the "Detachable" cable option above, input the field detachable cable total length needed in meters.
  10 These filed  shows if the unit requires an under water connector or not. No input required.
  11 Optional: If the probe is to be mounted inside a pipe. Select if a pipe flange is required or not.
  12 Optional: Pipe flange Material selected must be the same as the probe material.
  13 Optional: Pressured air can be used to clean the optics underwater. If you choose this option you may want to consider purchasing the Tribox to control the air flow. 
  14 This is the part number and description of the probe selected by the configurator based on your input above. Add the quantity needed
  15 This is the part number for the detachable cable if selected based on your input. Add the quantity needed. 
  16 If the probe type is "OPUS" then Select water Type from the dropdown menu 
  17 If the probe type is "OPUS" then Select Parameters from the dropdown list. The part number for the required calibration is displayed.  Add the quantity needed. 
  18 Select "Yes" if you want to use a wiper to clean the lenses. The wiper can not be used in conjunction with a Flow-Cell. No wiper option is available for the 0.3 mm and 50 mm path lengths. Add the quantity needed.
  19 This is the wiper blades kit to use with the path length selected above.
  20 Select "Yes" if the probe is to be connected to SDI-12 Datalogger. Add the quantity needed.
  21 The SDI-12 adaptor is required for SDI connection. 
  22 To connect the probe to a PC for setup, download or spot checking select an interface from the dropdown menu.  The G2plus interface is Highly recommended as it connects the probe directly to any USB3.0 port with no external power required. Add the quantity needed.
  23 Choose "Yes" if you have selected the detachable cable option so you do not have to remove the field cable when removing the probe from the field for calibration, setup or download.
  24 Optional sensor guard to protect the wiper and the lenses. Add the quantity needed.
  25 Select "Probe flow cell"  "only". No panel mount and no ultrasonic cleaning. Based on the path length selected. Add the quantity needed.
  26 Select "Probe flow cell"  "with panel" mount and no ultrasonic cleaning. Based on the path length selected. Add the quantity needed.
  27 Select "Probe flow cell" "With Panel & USC" (Panel mount & UltraSonic Cleaning). Based on the path length selected. Not available for 50 mm path length. Add the quantity needed.
  28 This is the part needed to calibrate the probe. Add the quantity needed.
  29 Select "Yes" if you want a deployment Buoy. Add the quantity needed.
  30 Select "Yes" if you want the mounting clamps to mount the probe to a wall. Add the quantity needed.
  31 This cable can extend the length of the field cable overground and can not be submerged. Select cable length from dropdown list. Add the quantity needed.
  32 The lenses on the NICO and OPUS can be replaced by the end user for damaged lenses or to upgrade to a different path length.
1- Select the new path length from the dropdown list.
2- Select material type from the dropdown list.
3- "Cable side" Socket mounted on the cable side is displayed.
4- "Sensor side" Socket mounted on the sensor side is displayed.
5- "PLA Cable side" Path Length Adapter on the cable side is displayed.
6-"PLA Sensor side" Path Length Adapter on the sensor side is displayed.
Note: 10-50 mm Path Length is the 10 mm Path Length downsized from 50 mm Path Length option
Add the quantity needed.
  33  Select path length from dropdown list for additional wiper blades. Add the quantity needed.
  34 Select a Tribox3 controler with or without WIFI option. Add the quantity needed.
  35 Select a Tribox mini controler with or without WIFI option. Add the quantity needed.
  36 Add additional items. Add description, Part number, Quantity and Price for each. 
  37 Add additional items. Add description, Part number, Quantity and Price for each. 
  38 Add additional items. Add description, Part number, Quantity and Price for each. 
  39 Add additional items. Add description, Part number, Quantity and Price for each. 
  40 Notes